Digital Portable Non-Nuclear Electronic Soil Density Gauge

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Still deciding? Get samples of US$ 3900/Set
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
51
Year of Establishment
2010-04-13
  • Digital Portable Non-Nuclear Electronic Soil Density Gauge
  • Digital Portable Non-Nuclear Electronic Soil Density Gauge
  • Digital Portable Non-Nuclear Electronic Soil Density Gauge
  • Digital Portable Non-Nuclear Electronic Soil Density Gauge
  • Digital Portable Non-Nuclear Electronic Soil Density Gauge
  • Digital Portable Non-Nuclear Electronic Soil Density Gauge
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
EDG2S
Application
Soil Test
Power Supply
220V
Certificate
ISO CE
Dry Density Accuracy
Within 3% of Standard Tests
Display
Touch Screen
Transport Package
Engineer Box
Specification
48X21X38 cm
Trademark
IWIN
Origin
Hebei, China
HS Code
9031809090
Production Capacity
2000sets/Month

Product Description

Product Description

 

New Type Upgraded Version Non Nuclear EDG Soil Electrical Density Gauge
Digital Portable Non-Nuclear Electronic Soil Density Gauge

The new type soil electric density gauge is on sale!

 

The soil nailing modeling process is canceled, and the non-destructive testing is truly achieved by using electromagnetic technology, which further reduces the testing time and increases the accuracy of the data.

 

If you need a detailed operation video, please send us an inquiry or contact us online.

 

Same price!

Digital Portable Non-Nuclear Electronic Soil Density Gauge

 
Product Parameters
Dry Density Accuracy
 
within 3% of standard tests
 
Moisture Content Range
 
typical compacted earth sites range
 
Moisture Content Accuracy
 
within 2% of standard tests
 
Power Li Ion battery
 
3.7V 4400mAh lithium battery
 
Display
 
Touch Screen
 

The operation of EDG introduces some new technologies that you need to be familiar with:

 

1. Soil model is the combination of soil electronic data and soil physical data input by users, and it is the basis of testing soil parameters in a similar soil characteristic area.

 

2. For soil modeling, EDG is required to collect electronic signals at different test points (the test points of this soil model are called soil testing). Each test point needs to collect an electronic signal.The maximum dry density of the soil measured in the laboratory is then fed into the instrument so that the electronic data are correlated with the physical data.

 

3. At least three test points (soil test) are required when making a soil model.The more test points, the more representative the model.Moreover, the greater the range of density and water content covered by the test points, the more accurate the soil model will be.

 

4. After the soil model is made, EDG can be used for field test. The test area is an area with the same physical characteristics as the tested soil that the experimenter intends to test.

 

5. A clay mold is usually made for each different test area.Different projects require different soil molds.Once the soil mold representing this area is successfully made, the soil characteristics of any Test point can be determined quickly and accurately by EDG through Field Test.

 

6. The actual test is the physical characteristics of soil calculated from the electronic data collected at the test point after the comparison of soil models.
Digital Portable Non-Nuclear Electronic Soil Density Gauge

 
Packaging & Shipping

 

Digital Portable Non-Nuclear Electronic Soil Density GaugeDigital Portable Non-Nuclear Electronic Soil Density GaugeDigital Portable Non-Nuclear Electronic Soil Density GaugeDigital Portable Non-Nuclear Electronic Soil Density GaugeDigital Portable Non-Nuclear Electronic Soil Density GaugeDigital Portable Non-Nuclear Electronic Soil Density Gauge
FAQ

 

Q: Are your company a trading one or a factory?

A: Factory+ trade (integration), More than 10 years focusing on test instruments field.

 

Q: After an order is placed, when to deliver?

A: Generally about 10-25days, If we have inventory, we can arrange shipment within 3 days Please be aware that our production lead times depend on specific items and item quantities.

 

Q: What about the warranty with after-sales services?

A: The testing machine is guaranteed for 12 months by gaotiejian, we can help you to repair your problem con troller freely, even it's not from our factory. After the warranty, the professional after-sale service team will provide perfect technical support and help guests solve problems encountered while using our product, handles guest problems and complaints in a professional and timely.

 

Q: What about the product' services and qualit?

A: Each instruments must be carried out 100% quality examination and test when shipping and delivery goods Product use training, each of our product provide video training to show you how to install operate We can arrange engineer to train the operation of equipment to customer s company when you need. products are widely recognized and trusted by users.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier